Title
Beyond sensitivity: a critical framework for analytical reliability, clinical validation, and point-of-care readiness of next-generation cardiovascular sensing technologies
AbstractCardiovascular sensing technologies have advanced considerably through innovations in molecular recognition, nanomaterials, signal amplification, device integration, and artificial intelligence (AI). Nevertheless, translating promising analytical performance into clinically reliable and point-of-care testing (POCT)-ready technologies remains a major challenge. This review presents a five-pillar framework for critically evaluating next-generation cardiovascular sensing platforms, encompassing (i) advanced molecular recognition and signal generation, (ii) advanced materials and signal engineering, (iii) integrated and multiplexed sensing architectures, (iv) intelligent data processing and decision support, and (v) adaptive, autonomous, and closedloop sensing. Representative developments in electrochemical, optical, surface-enhanced Raman scattering, field-effect transistor, microfluidic, paper-based, wearable, and implantable platforms are examined across major cardiovascular biomarkers and biological matrices. Particular attention is given to the interplay between analytical sensitivity, selectivity, matrix effects, reproducibility, clinical validation, and operational robustness. The review further examines the contributions and limitations of AI-assisted interpretation, multimarker detection, and continuous monitoring, emphasizing the distinction between laboratory-level performance and demonstrated clinical utility. An integrated evidence-based assessment incorporating analytical reliability, clinical validation, POCT suitability, operational robustness, and translational maturity is proposed to identify persistent gaps and guide future development. Ultimately, this framework shifts the evaluation of cardiovascular sensing from sensitivity-centered performance toward clinically meaningful, reproducible, and implementation-ready technologies
جدول حصص المواقع
Target journal(s) 1.Talanta....IF= 6.7 2. Analytical Chimica acta... IF= 6.1 3. Critical reviews in Analytical Chemistry.... IF= 7.7 · 0 / 5 أشخاص
| المؤلف | المبلغ | |
|---|---|---|
| المؤلف 1 - المراسل | سجّل الدخول لرؤية السعر | سجّل الدخول لحجز موقع |
| المؤلف 2 | سجّل الدخول لرؤية السعر | سجّل الدخول لحجز موقع |
| المؤلف 3 | سجّل الدخول لرؤية السعر | سجّل الدخول لحجز موقع |
| المؤلف 4 | سجّل الدخول لرؤية السعر | سجّل الدخول لحجز موقع |
| المؤلف 5 | سجّل الدخول لرؤية السعر | سجّل الدخول لحجز موقع |